The HUB-T Amseco Potter Hold Up Switch-Two Button provides two sets of momentary or latching DPDT contacts for actuating surveillance cameras or other security applications, in addition to the hold-up signal. The two sets of contacts may be used independently of each other, or they may be wired in series with a jumper wire for additional protection against false alarms. See illustration on page 2.
Installation
Install in accordance with UL 681. Devices should be installed so they cannot be observed by the public and so they can be operated inconspicuously. At least one shall be installed in each vault open during business hours. In banks they shall also be installed in offices commanding a view of the public space.