5499 - Silent Knight Distributed Power Module 9 amps

5499 - Silent Knight Distributed Power Module 9 amps
Manufacturer:  Silent Knight  SKU:  5499
Rating: [0]   Write a Review | Read Reviews
In Stock
Usually leaves our warehouse the same business day.

SPECIAL ORDER ITEM:
This item takes 2-3 business days to ship.

Price:  $419.95

Image Viewer  Show Picture 1Show Picture 2
stuff

The 5499 Silent Knight Distributed Power Module 9 amps is a 9 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls that have 9-32 VDC outputs.

Features:

  • UL Listed for 9 amps of notification power
  • Built-in synchronization for appliances from System Sensor(R), AMSECO, Faraday, Gentex(R), and Wheelock(R)
  • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems
  • Dip switches allow for easy reconfiguration
  • 24 VDC filtered output voltage
  • Four power-limited notification outputs; 2 Class A (Style Z) or 4 Class B (Style Y), or 1 Class A and 2 Class B
  • Additional continuous auxiliary output
  • 3 amps per output circuit
  • 2 inputs; 2 Class B (Style B) or 2 Class A (Style D)
  • Ground fault detector/indicator
  • Independent trouble relay
  • AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders
  • Stand alone operation.
  • Lightweight design adds to ease of installation and reduces shipping costs
  • Operates with most polarized, UL Listed notification devices
  • ANSI Cadence pattern output capability built-in
Rating: (0.00)   # of Ratings: 0   

There are no comments for this product.
Electrical Specifications
AC Input 120 VAC at 3.0A
Output 24 VDC at 9 A
Current Standby: 75 mA
Alarm: 205 mA
Auxiliary Power Circuit 1
Notification Circuits 4
Output Configuration 2 Class A (Style Z)
4 Class B (Style Y)
(1 Class A & 2 Class B)
Amps Per Output 3.0 (9.0 amps total)
Notification Circuit Output 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kW EOL resistor required on each Class B circuit
No. of Inputs 2
Input Configuration 2 Class B (Style Y) or 2 Class A (Style Z)
Input Voltage Range 9 - 32 VDC
Battery charging Capacity 35.0 AH
Mechanical Specifications
Dimensions 12.25” W x 16” H x 3” D
30.88 cm W x 40.64 cm H x 7.62 D cm
Operating Temp 32° to 120° F (0° to 49° C)
Humidity 93% non-condensing max.
Indicator Lights
AC power on Green
Battery trouble Yellow
Ground fault Yellow
Aux Trouble Yellow
Output troubles (1-4) Yellow
Installation Surface mount
Approvals NFPA 72
UL Listed
CSFM 7300-0559: 123
MEA 429-92-E
Vol. XII
Spec Sheet
Downloads: 80
Size: 493 KB

Installation Manual
Downloads: 99
Size: 1654 KB



Limited Support

In most cases, the installation or expansion of a commercial fire alarm system is determined by code requirements. There is federal, state, and local codes that come into play, specifying who must install fire alarm equipment, what type of equipment must be installed, where and how it must be installed. Failing to comply fully with any of these codes can result in denial of occupancy permits, fines, legal and financial liability.

Sorry we do not offer technical support for these products because of local codes that come into play specifying who must install fire alarm equipment and where and how it must be installed. To read more, visit the National Fire Alarm and Signaling Code website.