The Suberbus Zone Hard Wire Input Module adds eight supervised hardwire zones to Advent, Concord, Concord 4, Concord Express and UltraGard panels. Each module includes mounting hardware and eight 2.0k Ohm End-of-Line (EOL) resistors. Power for the module may be provided by the panel or an auxiliary 12V DC power supply.
SuperBus 2000 vs. SuperBus
SuperBus 2000 panels auto-address module unit numbers. When the panel is powered, a unique device ID number (pre-programmed at the factory) is automatically learned by the panel. Potential identical unit number conflicts and the need to manually set DIP switches are eliminated.
Older SuperBus panels can communicate with the 8Z input Module by manually setting the module's DIP switches.
SuperBus 2000 Panels
- Advent
- Concord (v2.0-later)
- Concord 4
- Concord Express (v4)
SuperBus Panels
- UltraGard
- Concord (v.1.0-1.6)
Installations
The module can be mounted:
- On a wall
- Inside an Advent cabinet
- Inside a Concord panel cabinet
- Inside a System Expansion Enclosure