The 449AT GE Photoelectric Smoke Detector is perhaps the most intelligent smoke detector on the market today. Smoke detectors are certainly crucial to any home security system, but those of us who aren't security experts might not know if we're even installing the unit in the right place! Luckily, the folks at GE thought about just that when they equipped the this Photoelectric Smoke Detector with a Self-Diagnostics capabilities, which includes automatic sensitivity testing. What this means is that the smoke detector continually monitors its own sensitivity and operational status, and provides a visual trouble indication if it drifts out of sensitivity range or fails internal diagnostics. That way you'll never run the risk of having your smoke detector installed improperly! Furthermore, the GE Photoelectric Smoke Detector has superior protection against fals alarms caused by dust, insects, RF and ambient light.
Features
- Intelligent self-diagnostics
- Field-replaceable optical chamber
- Low-profile design
- Plug-in terminal block
- Advanced false alarm immunity
- Meets NFPA 72 field sensitivity testing requirements without the need for external meters
- On-site maintenance alert
- Model 449CSRH activates local alarm for smoke-perfect for rooms where smoking is permitted
| Alarm @ Relay Specifications |
2.0 A @ 28.0 V |
| Alarm Current Consumption [Nominal] |
15.0 mA |
| Color |
White |
| Current Consumption w/ Alarm[Nominal] |
15.0 mA |
| Detection (Operating) Range |
3.1 to 1%/ ft max; 3.1 to.5%/ft max |
| Detector Head Depth [Nominal] |
1.85 in |
| Detector Head Diameter [Nominal] |
6.1 in |
| Field Wiring Size [Minimum] |
14.0 AWG |
| Field Wiring Size [Maximum] |
24.0 AWG |
| Heat Detection Specifications - Fixed [Nominal] |
135.0 °F |
Heat Detection Specifications - Rate of Rise |
>105°F and Rate of Rise 15°F/min |
| Height [Nominal] |
1.85 in |
| Maximum Ripple [Maximum] |
10.00% |
| Operating Humidity [Minimum] |
0.0 % RH |
| Operating Humidity [Maximum] |
95.0 % RH |
| Operating Temperature [Minimum] |
32.0 °F |
| Operating Temperature [Maximum] |
120.0 °F |
| Operating Voltage [Minimum] |
5.1 V |
| Operating Voltage [Maximum] |
27.0 V |
| Packaging Basis [Nominal] |
10.0 per carton |
| Polarity Reverse Current [Nominal] |
10.0 mA |
| Regulatory Approval |
UL 268 |
| Relay @ Contact Rating |
500.0 mA @ 36.0 V |
| Sensitivity - Photoelectric [Minimum] |
0.05% |
| Sensitivity - Photoelectric [Maximum] |
3.10% |
| Sensitivity - Photoelectric [Nominal] |
3.10% |
| Standby Current Consumption [Nominal] |
70.0 µA |