PC2W - System Sensor Fire Alarm Ceiling Mount Horn Strobe White

PC2W - System Sensor Fire Alarm Ceiling Mount Horn Strobe White
Manufacturer:  System Sensor  SKU:  PC2W
Rating: [1]   Write a Review | Read Reviews
In Stock
Usually leaves our warehouse the same business day.

SPECIAL ORDER ITEM:
This item takes 2-3 business days to ship.

Price:  $45.53

Image Viewer  Show Picture 1
stuff

General

System Sensor(R) SpectrAlert(R) Advance selectable-output horns, strobes and horn/strobes are rich with features guaranteed to cut installation times. The SpectrAlert Advance series of notification appliances is designed to simplify your installations, with features such as: plug-in designs, instant feedback messages to ensure correct installation of individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon, or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.

Features

  • Plug-in design.
  • Same mounting plate for wall- and ceiling-mount units.
  • Shorting spring on mounting plate for continuity check before installation.
  • Captive mounting screw.
  • Tamper-resistance capability.
  • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185.
  • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela.
  • Outdoor wall and ceiling products.
  • Outdoor products rated from -40deg.F and 151deg.F (-40deg.C and 66deg.C).

SpectrAlert Advance products allow you to choose:

  • 12 or 24 volts.
  • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of a rear-mounted slide switch and front viewing window.
  • Horn tones and volume by way of a rotary switch.
  • The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two-wire and four-wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between -40deg.F and 151deg.F (-40deg.C and 66deg.C) in wet or dry applications.
Rating: (5.00)   # of Ratings: 1   


Sort: New to Old RE-SORT REVIEWS:

Showing comments 1-1 of 1
1. New on 3/14/2013, said:

THIS IS GREAT FOR OUR CONDO!!! Not to loud not to quiet! GREAT! GREAT! GREAT!!!

Was this comment helpful? yes no   (2 people found this comment helpful, 1 did not)
Showing comments 1-1 of 1
Standard Operating Temperature 32°F to 120°F (0°C to 49°C)
K Series Operating Temperature –40°F to 151°F (–40°C to 66°C)
Humidity Range 10% to 93% non-condensing (indoor products)
Strobe Flash Rate 1 flash per second
Nominal Voltage regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.
Operating Voltage Range 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). NOTE: P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 15/75 cd.
Input Terminal Wire Gauge 12 to 18 AWG (3.31 to 0.821 mm²)
Ceiling-Mount Dimensions
(Including Lens)
6.8" diameter x 2.5" deep (17.3 cm diameter x 6.4 cm deep)
Wall-Mount Dimensions
(Including Lens)
5.6" H x 4.7" W x 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D)
Horn Dimensions 5.6" H x 4.7" W x 1.3" D (14.2 cm H x 11.9 cm W x 3.3 cm D)
Accessories

Installation Manual
Downloads: 103
Size: 1048 KB

Data Sheet
Downloads: 107
Size: 545 KB



Limited Support

In most cases, the installation or expansion of a commercial fire alarm system is determined by code requirements. There is federal, state, and local codes that come into play, specifying who must install fire alarm equipment, what type of equipment must be installed, where and how it must be installed. Failing to comply fully with any of these codes can result in denial of occupancy permits, fines, legal and financial liability.